What cure temperature range does this prepreg require for autoclave processing?
The prepreg requires an autoclave cure temperature range of 80°C to 120°C. Follow the relevant technical data sheet and approved cure schedule for best results.
What width and consolidated thickness should I plan for when laying out the laminate?
Plan for a 1250 mm material width and 0.45 mm consolidated thickness. The stated thickness is the consolidated value for laminate planning.
How long can the material be kept before use, both at room temperature and in a freezer?
The material has a 30-day out-life at 20°C and can be kept for up to 12 months in a freezer at -18°C. Please follow the applicable thawing and storage instructions before use.